NIDEK GS-1 Gonioscope

Brand:

Enquire

At a glance:
  • AUTOMATED 360° COLOUR GONIOSCOPY: Captures the entire iridocorneal angle in real-colour photographs using a unique 16-mirror prism lens, providing comprehensive documentation of anterior chamber angle anatomy.
  • RAPID AUTOMATED IMAGE: Completes full 360° image acquisition in approximately 16 seconds per eye, with the entire examination taking around two minutes.
  • DIGITAL DOCUMENTATION FOR GLAUCOMA MANAGEMENT: Creates objective, high-resolution images that can be stored, reviewed and compared over time, eliminating the need for hand-drawn gonioscopy records.
  • MULITPLE VIEWING & STITCHING OPTIONS: Automatically generates single, circular and linear stitched images, allowing clinicians to assess both localised pathology and the entire anterior chamber angle.
  • NAVIS-EX INTEGRATION FOR LONGITUDINAL: Follow-Up Optional GS Viewer software enables image comparison, focus stacking and long-term glaucoma monitoring within the NIDEK NAVIS-EX platform.
  • More information below.

Download Brochure

  • CALL TODAY 0345 646 1438

Automated 360° Gonioscopy for Modern Glaucoma Care

The NIDEK GS-1 Gonioscope is an innovative automated gonioscopy system that transforms the way clinicians assess and document the anterior chamber angle. Designed to simplify one of ophthalmology’s most technically demanding examinations, the GS-1 produces high-resolution 360° colour images of the iridocorneal angle quickly, consistently and with minimal operator dependency.

By combining automated image acquisition with comprehensive digital documentation, the GS-1 supports more efficient glaucoma assessment, improved clinical communication and confident long-term patient management.

Bringing Objectivity to Gonioscopy

Conventional gonioscopy remains the gold standard for assessing the anterior chamber angle, but it is highly dependent on operator skill and does not provide permanent photographic documentation.

The GS-1 overcomes these challenges by automatically capturing and storing detailed colour images of the entire angle, allowing clinicians to review findings at any time, compare previous examinations and share images with colleagues or referring practitioners.

Key Features

Automated Circumferential Goniophotography

The GS-1 uses an internal rotating optical system with a specially designed 16-surface multimirror prism to automatically photograph the complete iridocorneal angle.

Benefits include:

  • Complete 360° angle documentation
  • Consistent image acquisition
  • Reduced operator variability
  • Comprehensive angle assessment
  • Objective clinical records

The automated process ensures repeatable imaging whilst reducing dependence on operator technique.

Unique 16-Mirror Prism Lens

The specially developed multimirror prism captures images from 16 separate directions, providing full circumferential coverage of the anterior chamber angle.

Each sector is photographed at multiple focal depths, enabling detailed visualisation of angle structures across the entire circumference.

Multiple Focus Image Capture

Each angle segment is captured in 17 different focal planes, allowing the clinician to visualise structures at varying depths.

This enables:

  • Improved angle visualisation
  • Enhanced assessment of pathology
  • Greater image clarity
  • Better clinical confidence

The system automatically selects the optimal images for review and stitching.

Intelligent Image Stitching

Following acquisition, the GS-1 automatically generates:

  • Circular stitched images
  • Linear stitched images
  • Individual high-resolution angle images

These different viewing formats make it easier to assess both localised abnormalities and the entire angle anatomy.

Digital Documentation

Unlike traditional gonioscopy, the GS-1 permanently records examination findings.

Advantages include:

  • Objective patient records
  • Easier follow-up
  • Improved referral communication
  • Enhanced teaching opportunities
  • Better patient education

Clinicians no longer need to rely on subjective sketches within patient notes.

High-Resolution Colour Imaging

The system captures true-colour images that clearly demonstrate:

  • Trabecular meshwork
  • Schwalbe’s line
  • Scleral spur
  • Pigmentation
  • Peripheral anterior synechiae
  • Neovascularisation
  • Angle closure

Detailed colour photography improves interpretation and clinical decision-making.

Comfortable Gel Immersion Examination

Rather than contacting the cornea directly, the GS-1 uses a dedicated coupling gel to improve patient comfort during imaging.

The multimirror prism is designed not to contact the corneal surface, helping create a more comfortable examination experience.

Fast Automated Workflow

The examination process has been designed for efficiency.

Typical performance includes:

  • Approximately 16 seconds image capture per eye
  • Around two minutes total examination time
  • Simple patient alignment
  • Automatic acquisition
  • Minimal operator intervention

This supports high patient throughput in busy glaucoma clinics.

NAVIS-EX & GS Viewer Integration

When paired with the optional GS Viewer software, the GS-1 offers:

  • Longitudinal patient monitoring
  • Side-by-side examination comparison
  • Focus stacking
  • Database management
  • Network integration

This allows clinicians to assess disease progression and treatment outcomes over time.

Clinical Applications

Glaucoma Assessment

Provides comprehensive documentation of anterior chamber angle anatomy to support glaucoma diagnosis and management.

Angle Closure Evaluation

Accurately documents narrow and closed angles whilst allowing detailed review during clinical assessment.

MIGS Planning & Follow-Up

Supports pre-operative assessment and post-operative evaluation of minimally invasive glaucoma surgery (MIGS) devices and outcomes.

Laser Iridotomy & Surgical Documentation

Provides objective photographic documentation before and after laser peripheral iridotomy and other anterior segment procedures.

Long-Term Disease Monitoring

Digital image storage enables clinicians to monitor progression of pigment dispersion, synechiae, neovascularisation and other angle abnormalities over time.

Benefits for Your Practice

Improve Diagnostic Confidence

Objective 360° imaging provides a comprehensive view of angle anatomy whilst reducing operator variability associated with conventional gonioscopy.

Enhance Clinical Documentation

Permanent digital records improve patient management, referrals and medico-legal documentation.

Increase Clinic Efficiency

Automated acquisition allows trained staff to perform image capture, enabling clinicians to focus on assessment and treatment planning.

Support Collaborative Care

Digital images can be shared easily with colleagues, hospital eye departments and referring practitioners, improving communication across glaucoma pathways.

Improve Patient Understanding

High-resolution colour photographs provide an excellent visual aid for explaining glaucoma, angle anatomy and treatment recommendations to patients.

Ideal For

The NIDEK GS-1 Gonioscope is ideally suited to:

  • Glaucoma clinics
  • Hospital eye departments
  • Ophthalmology practices
  • Specialist glaucoma services
  • Academic institutions
  • Community ophthalmology services

Its combination of automated imaging, digital documentation and advanced software integration makes it an excellent solution for modern glaucoma assessment and long-term patient management.

Why Buy from Birmingham Optical?

Birmingham Optical provides:

  • Expert glaucoma imaging consultation
  • Professional installation and clinical training
  • Dedicated technical and application support
  • Ongoing servicing and maintenance
  • Access to the latest NIDEK diagnostic technologies

As the exclusive distributor of NIDEK ophthalmic equipment across the UK and Ireland, Birmingham Optical provides comprehensive support to help you maximise the value of your investment.

Find Out More

Discover how the NIDEK GS-1 Gonioscope can transform glaucoma assessment through automated 360° angle imaging, objective documentation and improved clinical workflow.

Contact Birmingham Optical today to speak with our equipment specialists on  0808 123 2020 or email [email protected]

At Birmingham Optical we also supply a variety of accessories and consumables, which would be relevant to this product. Please visit our store here

  • NIDEK Automated Gonioscopy Clinical Cases Download
  • NIDEK GS-1 Gonioscope Promotional Flyer Download