NIDEK NT-1P Non-Contact Tono/Pachymeter

Brand:

Enquire

At a glance:
  • COOMBINED NON-CONTACT TONOMETRY & OPTICAL PACHYMETRY: Measure intraocular pressure (IOP) and central corneal thickness (CCT) in a single fully automated examination, with automatic IOP correction based on corneal thickness for more informed glaucoma assessment.
  • FULLY AUTOMATED EYE DETECTIONI & MEASUREMENT: The NIDEK Eye Detection Camera automatically detects, aligns and measures both eyes with virtually no operator input, improving efficiency and consistency.
  • GENTLE AUTOMATIC PUFF CONTROL (APC) Intelligent air puff technology automatically adjusts the air pressure to the minimum required for each patient, delivering a quieter, gentler and more comfortable examination.
  • AUTOMATIC IOP COMPENSATION: Using Corneal Thickness Integrated optical pachymetry measures corneal thickness and automatically calculates corrected IOP values, supporting more accurate glaucoma assessment.
  • FLEXIBLE, SPACE-SAVING DESIGN: A 7-inch tilt-and-swivel touchscreen allows installation against a wall, in a corner or within a traditional consulting room, maximising valuable clinical space.
  • More information below.

Download Brochure

  • CALL TODAY 0808 123 2020

Comprehensive Glaucoma Assessment in One Intelligent System

The NIDEK NT-1P Non-Contact Tono/Pachymeter combines fully automated non-contact tonometry with integrated optical pachymetry to deliver fast, accurate and comfortable glaucoma assessment. By measuring both intraocular pressure and central corneal thickness in a single examination, the NT-1P provides clinicians with the additional clinical information needed to interpret IOP measurements with greater confidence.

Designed for busy optometry practices, ophthalmology clinics and hospital eye departments, the NT-1P streamlines patient flow whilst enhancing both operator efficiency and patient comfort through intelligent automation and advanced eye tracking.

Smarter Tonometry for Modern Practice

Accurate glaucoma assessment requires more than simply measuring intraocular pressure.

Corneal thickness can significantly influence IOP readings, which is why the NT-1P combines non-contact tonometry with optical pachymetry to automatically calculate corrected IOP values during the examination.

Benefits include:

  • Faster glaucoma assessments
  • Improved clinical confidence
  • Greater patient comfort
  • Reduced operator workload
  • More meaningful IOP interpretation

The result is a complete glaucoma screening solution in one compact instrument.

Key Features

Combined Tonometry & Pachymetry

The NT-1P performs both non-contact tonometry and optical pachymetry within a single automated examination.

Benefits include:

  • Intraocular pressure measurement
  • Central corneal thickness measurement
  • Corrected IOP calculation
  • Reduced patient movement
  • Improved workflow

This eliminates the need for separate pachymetry equipment during routine glaucoma assessments.

Fully Automated Measurement

Using the integrated NIDEK Eye Detection Camera, the system automatically detects the patient’s eyes, aligns the instrument and performs measurements without requiring button presses.

Benefits include:

  • Automatic eye detection
  • Auto alignment
  • Auto measurement
  • Automatic right-to-left eye transition
  • Consistent examination workflow

Automation improves repeatability whilst allowing clinicians to concentrate on patient care.

Non-Contact Optical Pachymetry

The NT-1P measures central corneal thickness using infrared optical technology without touching the eye.

Features include:

  • Measurement range: 300–800 μm
  • Non-contact examination
  • Fast acquisition
  • Comfortable patient experience
  • Excellent repeatability

The optical design removes the need for anaesthetic drops or contact probes.

Automatic IOP Correction

Measured corneal thickness is automatically used to calculate a corrected intraocular pressure value.

Benefits include:

  • Improved glaucoma assessment
  • More accurate IOP interpretation
  • Simplified clinical workflow
  • Reduced manual calculations
  • Greater diagnostic confidence

This provides clinicians with more clinically meaningful IOP information during every examination.

Automatic Puff Control (APC)

The NT-1P intelligently adjusts air pressure based on previous measurements.

Advantages include:

  • Softer air puff
  • Reduced examination noise
  • Greater patient comfort
  • Less patient apprehension
  • Consistent measurements

Only the minimum air pressure required is delivered for each patient.

3D Auto Tracking & Auto Shot

Continuous X, Y and Z eye tracking ensures accurate alignment before the measurement is automatically captured.

Benefits include:

  • Faster examinations
  • Improved repeatability
  • Accurate positioning
  • Reduced operator dependency
  • Reliable measurements

Automatic measurement begins once correct alignment has been achieved.

Air-Nozzle Contact Sensor

An integrated safety sensor monitors the distance between the nozzle and the patient’s eye.

If contact is detected:

  • Measurement stops immediately
  • The measuring head retracts
  • The operator is alerted

This provides additional reassurance for both patients and clinicians.

Flexible Touchscreen Design

The 7-inch colour touchscreen tilts and swivels to suit a variety of consulting room layouts.

Benefits include:

  • Wall installation
  • Corner installation
  • Improved ergonomics
  • Better patient positioning
  • Efficient use of consulting room space

Its flexible design makes the NT-1P suitable for practices of all sizes.

Voice Guidance

Integrated voice prompts are available in nine languages.

Benefits include:

  • Easier patient communication
  • Reduced operator instruction
  • Improved patient cooperation
  • Faster examinations

Voice guidance helps create a smooth and reassuring examination experience.

Flexible Control Options

The NT-1P can be configured with optional:

  • Wired hand controller
  • Wireless hand controller
  • Joystick
  • Tablet control software
  • Wireless LAN

Tablet screen mirroring allows remote operation without compromising functionality.

Built-in Printer & Connectivity

The system includes:

  • Integrated thermal printer
  • USB connectivity
  • LAN connection
  • RS-232 interface
  • Optional Wireless LAN

These features simplify data management and integration with practice management systems.

Clinical Applications

Glaucoma Screening

Simultaneous IOP and corneal thickness measurements support more comprehensive glaucoma assessment and long-term patient monitoring.

Routine Eye Examinations

Fast, automated measurements integrate seamlessly into pre-test workflows for comprehensive eye examinations.

Hospital Eye Departments

Ideal for high-volume outpatient clinics requiring efficient, repeatable tonometry and pachymetry.

Corneal Assessment

Optical pachymetry supports evaluation of corneal thickness for glaucoma management, refractive surgery assessment and anterior segment investigations.

Benefits for Your Practice

Improve Clinical Efficiency

Fully automated operation shortens examination times whilst reducing operator workload.

Enhance Patient Comfort

Automatic Puff Control, gentle nozzle design and non-contact pachymetry create a more comfortable examination.

Increase Diagnostic Confidence

Automatic correction of IOP using measured corneal thickness provides more clinically meaningful results.

Maximise Practice Space

The flexible touchscreen and compact design allow installation in virtually any consulting room configuration.

Future-Proof Your Workflow

Tablet control, optional wireless operation and advanced connectivity ensure seamless integration into modern digital practices.

Ideal For

The NIDEK NT-1P Non-Contact Tono/Pachymeter is ideally suited to:

  • Independent optometry practices
  • Multiple practice groups
  • Hospital eye departments
  • Ophthalmology clinics
  • Glaucoma specialists
  • High-volume pre-test areas

Its combination of intelligent automation, integrated pachymetry and automatic IOP correction makes it an excellent solution for comprehensive glaucoma assessment.

Why Buy from Birmingham Optical?

Birmingham Optical provides:

  • Expert glaucoma diagnostics consultation
  • Professional installation and clinical training
  • Dedicated technical and application support
  • Preventative servicing and maintenance
  • Access to the latest NIDEK diagnostic technologies

As the exclusive distributor of NIDEK ophthalmic equipment across the UK and Ireland, Birmingham Optical helps practices implement innovative diagnostic solutions that improve efficiency, workflow and patient care.

Find Out More

Discover how the NIDEK NT-1P Non-Contact Tono/Pachymeter can transform your glaucoma screening workflow with fully automated operation, integrated optical pachymetry and automatic IOP correction. Combining intelligent automation, exceptional patient comfort and comprehensive clinical data, the NT-1P delivers a fast and reliable solution for today’s modern eye care practice.

Contact Birmingham Optical today to speak with one of our optical equipment specialists on 0808 123 2020 or [email protected] 

At Birmingham Optical we also supply a variety of smaller items, accessories and consumables, please visit our store here

  • NIDEK NT-1P Non-contact Tonometer Product Brochure Download