NIDEK Mirante Multi Modal OCT-A

Brand:

Enquire

At a glance:
  • THE ULTIMATE-MODAL RETINAL IMAGING PLATFORM: Combines Spectral-Domain OCT, OCT Angiography (OCT-A), Scanning Laser Ophthalmoscopy (SLO) and multiple retinal imaging modalities in a single integrated system.
  • ULTRA-WIDEFIELD IMAGING UP TO 163°: Optional wide-field adapter captures an ultra-wide 163° view, enabling detailed assessment from the macula to the far retinal periphery.
  • COMPREHENSIVE IMAGING MODALITIES: Capture Colour SLO, OCT, OCT-A, Fluorescein Angiography (FA), Indocyanine Green Angiography (ICG), Blue & Green Fundus Autofluorescence (FAF) and unique Retro Mode imaging from one platform.
  • ULTRA 4K HD IMAGING WITH FlexTrack TECHNOLOGY: Produces exceptionally detailed retinal images with up to 4096 × 4096 pixel resolution, while FlexTrack compensates for poor fixation to improve image quality.
  • ADVANCED OCT ANGIOGRAPHY & GLAUCOMA ANALYSIS: Provides non-invasive retinal vascular imaging, vessel density mapping, FAZ analysis, wide-area OCT scanning and comprehensive glaucoma assessment tools.
  • More information below...

Download Brochure

  • CALL TODAY 0345 646 1438

The Complete Retinal Imaging Solution

The NIDEK Mirante Multi-Modal OCT-A is one of the most comprehensive retinal imaging platforms available, bringing together multiple advanced imaging technologies within a single, highly integrated system. Designed for ophthalmologists, retinal specialists and hospital eye departments, the Mirante enables clinicians to visualise retinal structure, retinal vasculature and choroidal pathology with exceptional clarity while streamlining clinical workflow.

By combining high-definition Scanning Laser Ophthalmoscopy (SLO), Spectral-Domain OCT, OCT Angiography and ultra-widefield retinal imaging, the Mirante provides an outstanding level of diagnostic information without the need for multiple standalone devices.

A Truly Multi-Modal Imaging Platform

Modern retinal diagnosis often requires several imaging modalities to fully understand retinal disease. Rather than moving patients between multiple instruments, the Mirante captures numerous complementary imaging modalities from one intuitive platform.

Available imaging includes:

  • Colour Scanning Laser Ophthalmoscopy (SLO)
  • Spectral-Domain OCT
  • OCT Angiography (OCT-A)
  • Fluorescein Angiography (FA)
  • Indocyanine Green Angiography (ICG)
  • Blue Fundus Autofluorescence (Blue-FAF)
  • Green Fundus Autofluorescence (Green-FAF)
  • Retro Mode imaging

This comprehensive approach supports confident diagnosis across a wide range of retinal and choroidal diseases.

Key Features

Ultra-Widefield Retinal Imaging

With the optional wide-field adapter, the Mirante captures an impressive 163° field of view, allowing clinicians to evaluate pathology extending from the macula to the far retinal periphery.

Benefits include:

  • Wider retinal assessment
  • Improved peripheral pathology detection
  • Enhanced retinal detachment evaluation
  • Comprehensive vascular assessment
  • Better documentation of peripheral lesions

Ultra-widefield imaging provides valuable additional clinical information compared with conventional retinal imaging systems.

Ultra 4K HD Image Quality

The Mirante delivers image resolution of up to 4096 × 4096 pixels, providing remarkable detail across every retinal layer.

Benefits include:

  • Exceptional image clarity
  • High magnification without significant loss of detail
  • Improved capillary visualisation
  • Better identification of subtle retinal pathology
  • Enhanced diagnostic confidence

Combined with image averaging, clinicians obtain highly detailed retinal images even in challenging cases.

FlexTrack Image Stabilisation

NIDEK’s FlexTrack technology compensates for unstable fixation by correcting image distortion during acquisition.

Advantages include:

  • Improved image quality
  • Reduced motion artefacts
  • Better averaging performance
  • More reliable examinations
  • Improved imaging in patients with poor fixation

This technology helps achieve consistently high-quality imaging across a broad patient population.

Advanced OCT Imaging

The Mirante incorporates high-speed Spectral-Domain OCT with wide-area scanning capability.

Features include:

  • Retina Map up to 16.5 × 12 mm
  • Ultra Fine scanning mode
  • Tracing HD Plus
  • EDI (Enhanced Depth Imaging)
  • High-resolution B-scans

The large scan area enables simultaneous assessment of both the macula and optic nerve head within a single acquisition.

OCT Angiography (OCT-A)

Optional AngioScan OCT-A provides detailed, dye-free visualisation of retinal and choroidal microvasculature.

Clinical analysis includes:

  • Vessel density mapping
  • Perfusion density mapping
  • Automatic FAZ detection
  • Multiple segmented retinal slabs
  • Projection artefact removal

This allows clinicians to evaluate retinal circulation without intravenous dye injection.

Colour SLO Imaging

Unlike conventional fundus photography, the Mirante uses three dedicated RGB detectors to simultaneously image different retinal depths.

Benefits include:

  • Superior colour reproduction
  • Excellent retinal contrast
  • Adjustable colour histogram
  • Single-shot RGB imaging
  • Enhanced visualisation of retinal pathology

Clinicians can customise image appearance to resemble either slit lamp or fundus camera views.

Fluorescein & ICG Angiography

The Mirante supports both Fluorescein Angiography (FA) and Indocyanine Green Angiography (ICG) with simultaneous image acquisition.

Features include:

  • Simultaneous FA and ICG capture
  • HD dynamic angiography
  • Static angiography
  • Auto Gain Control (AGC)
  • Live infrared alignment

Simultaneous angiography improves workflow whilst ensuring early vascular phases are captured accurately.

Blue & Green Fundus Autofluorescence

The Mirante offers both Blue-FAF and Green-FAF imaging to evaluate retinal pigment epithelium health.

Benefits include:

  • Early AMD assessment
  • Geographic atrophy monitoring
  • Macular dystrophy evaluation
  • RPE analysis
  • Improved macular assessment

Green FAF provides improved visualisation beneath the macula by reducing xanthophyll interference.

Unique Retro Mode Imaging

Exclusive to NIDEK, Retro Mode uses scattered infrared light to highlight subtle chorioretinal abnormalities.

Retro Mode is particularly useful for visualising:

  • Drusen
  • Choroidal abnormalities
  • Retinal oedema
  • Pigment epithelial changes
  • Subtle retinal elevations

This non-invasive imaging modality provides additional diagnostic information unavailable with conventional retinal imaging.

Fly Through Technology

The innovative Fly Through function synchronises OCT scans with other imaging modalities, allowing clinicians to navigate retinal structures whilst viewing corresponding multimodal images.

Benefits include:

  • Improved lesion localisation
  • Better multimodal correlation
  • Enhanced clinical interpretation
  • Efficient disease evaluation

This feature strengthens structural and functional assessment of retinal disease.

Intuitive Clinical Workflow

The Mirante has been designed for efficient clinical operation through:

  • One-touch image optimisation
  • Simple touchscreen interface
  • Automated image registration
  • Summary view of multimodal images
  • Side-by-side comparison tools

These features simplify operation whilst supporting busy retinal clinics.

Clinical Applications

Medical Retina

Supports diagnosis and monitoring of:

  • Age-related macular degeneration (AMD)
  • Diabetic retinopathy
  • Retinal vein occlusions
  • Central serous chorioretinopathy
  • Epiretinal membranes

The combination of structural and vascular imaging improves clinical decision-making.

Glaucoma Assessment

Wide-area OCT and glaucoma analysis provide comprehensive evaluation of the optic nerve head and retinal nerve fibre layer.

Peripheral Retinal Disease

Ultra-widefield imaging supports assessment of:

  • Retinal tears
  • Retinal detachment
  • Peripheral vascular disease
  • Peripheral retinal degeneration

The 163° field of view significantly expands retinal documentation.

Choroidal Disease

FA, ICG and Retro Mode imaging allow detailed assessment of choroidal pathology and vascular abnormalities.

Benefits for Your Practice

Consolidate Multiple Imaging Systems

Replace several standalone retinal imaging devices with one integrated multimodal platform, reducing equipment requirements and improving workflow.

Improve Diagnostic Confidence

The combination of OCT, OCT-A, SLO, angiography and autofluorescence provides a more complete understanding of retinal disease.

Increase Clinical Efficiency

Integrated imaging modalities reduce patient movement between devices and streamline retinal assessment.

Future-Proof Your Imaging Service

Expandable hardware and software options allow practices to add functionality as clinical requirements evolve.

Enhance Patient Care

Comprehensive multimodal imaging supports earlier diagnosis, more accurate monitoring and improved treatment planning across a wide range of retinal conditions.

Ideal For

The NIDEK Mirante Multi-Modal OCT-A is ideally suited for:

  • Retina specialists
  • Ophthalmology clinics
  • Hospital eye departments
  • Medical retina services
  • Academic institutions
  • Specialist diagnostic centres

Its combination of multimodal imaging, ultra-widefield capability and advanced OCT technology makes it one of the most versatile retinal imaging platforms available.

Why Buy from Birmingham Optical?

Birmingham Optical provides:

  • Expert retinal imaging consultation
  • Professional installation and clinical training
  • Dedicated technical and application support
  • Ongoing servicing and preventative maintenance
  • Access to the latest NIDEK ophthalmic technologies

As the exclusive distributor of NIDEK ophthalmic equipment across the UK and Ireland, Birmingham Optical offers comprehensive support throughout the lifetime of your investment.

Find Out More

Discover how the NIDEK Mirante Multi-Modal OCT-A can transform retinal diagnostics with comprehensive multimodal imaging, ultra-widefield capability and advanced OCT angiography in one integrated platform.

Contact Birmingham Optical today to speak with our equipment specialists on  0808 123 2020 or  email [email protected]

At Birmingham Optical we also supply a variety of accessories and consumables, which would be relevant to this product. Please visit our store here

  • NIDEK Mirante Clinical Cases Download
  • NIDEK Article - Presumed Tenofovir Toxcity Download
  • NIDEK Mirante Clinical Case - Scanning laser ophthalmoscopy Download
  • NIDEK Clinical Case - Clinical Benefits of Mirante Download