  • 250,000 A-SCANS PER SECOND HIGH SPEED OCT: Captures ultra-fast, high-resolution OCT images at 250kHz, delivering approximately three times faster imaging than the previous generation while reducing motion artefacts and improving patient comfort.
  • WIDE & DEEP RETINAL IMAGING: Acquires 16.5mm wide B-scans and 15 × 12mm Retina Maps with an impressive 4.2mm scan depth, enabling comprehensive assessment of both retinal and optic nerve pathology in a single scan.
  • ADVANCED DEEP LEARNING ANALYTICS: AI-powered segmentation and Structural Normality Mapping (SN Map) improve glaucoma and retinal analysis by reducing segmentation errors and highlighting subtle structural abnormalities.
  • DESIGNED FOR HIGH-VOLUME CLINICS: Auto Alignment, Auto Switch, preset scan protocols and intuitive software streamline image acquisition, helping improve workflow and diagnostic efficiency.
  • COMPREHENSIVE GLAUCOMA & RETINA ASSESSMENT: Advanced glaucoma analysis, long axial length normative database and optional OCT Angiography provide exceptional diagnostic capability for glaucoma, retinal vascular disease and myopic patients.
  • More information below.

Download Brochure

  • CALL TODAY 0345 646 1438

Faster Workflow Without Compromising Diagnostic Confidence

The NIDEK RS-1 Glauvas OCT is NIDEK’s next-generation Spectral-Domain Optical Coherence Tomography platform, designed specifically for high-volume ophthalmology clinics and hospital eye departments. Combining ultra-fast scan speeds, wide-field imaging and powerful deep learning analytics, the RS-1 Glauvas delivers exceptional diagnostic confidence whilst significantly improving clinical workflow.

Whether assessing glaucoma, retinal disease or highly myopic eyes, the RS-1 Glauvas provides clinicians with detailed structural imaging, advanced analysis tools and intelligent automation that support faster, more informed clinical decisions.

High-Speed Imaging for Busy Clinics

The RS-1 Glauvas incorporates one of the fastest scan engines in its class, capturing 250,000 A-scans per second.

This exceptional speed offers numerous clinical advantages:

  • Reduced examination time
  • Improved patient comfort
  • Fewer motion artefacts
  • Better image quality
  • Increased patient throughput

The higher scan speed is particularly beneficial when imaging elderly patients, children or those with unstable fixation.

Key Features

250kHz High-Speed OCT

The RS-1 Glauvas captures images approximately three times faster than its predecessor, helping clinicians obtain highly detailed retinal scans whilst minimising patient movement.

Benefits include:

  • 250,000 A-scans per second
  • Faster examinations
  • Improved workflow
  • Greater patient comfort
  • Excellent image clarity

Rapid acquisition supports efficient imaging without compromising diagnostic quality.

Wide & Deep Retinal Imaging

The system offers exceptionally large scan dimensions:

  • 16.5mm Line Scan
  • 15 × 12mm Retina Map
  • 4.2mm Scan Depth

This allows clinicians to visualise:

  • Macula
  • Optic nerve head
  • Temporal vascular arcade
  • Posterior pole
  • Myopic retinal anatomy

The increased scan depth is particularly valuable when imaging highly myopic eyes and assessing deeper retinal structures.

Advanced Deep Learning Segmentation

The RS-1 Glauvas incorporates AI-powered segmentation algorithms that improve layer detection, even in eyes with significant pathology or media opacity.

Benefits include:

  • Reduced segmentation errors
  • Fewer false positives
  • Improved normative analysis
  • Greater diagnostic confidence
  • Enhanced reporting accuracy

Deep learning analysis helps clinicians interpret scans more efficiently while improving consistency between examinations.

Structural Normality Map (SN Map)

Developed using deep learning technology, the Structural Normality Map (SN Map) highlights structural abnormalities layer by layer, making subtle retinal changes easier to identify.

Advantages include:

  • Rapid identification of abnormalities
  • Early retinal disease detection
  • Improved glaucoma screening
  • Simplified scan interpretation

The SN Map supports clinicians by drawing attention to clinically significant changes that may otherwise be overlooked.

Advanced Glaucoma Analysis

The RS-1 Glauvas provides comprehensive glaucoma assessment through detailed analysis of:

  • Retinal Nerve Fibre Layer (RNFL)
  • Ganglion Cell Complex (GCC)
  • Optic nerve head
  • Thickness maps
  • Normative databases

Summary analysis combines retinal and glaucoma information within a single report, streamlining interpretation during routine clinics.

Long Axial Length Normative Database

The system includes a dedicated normative database designed for patients with axial myopia.

Features include:

  • Axial length compensation
  • Scan width correction
  • Improved glaucoma assessment
  • Reduced measurement bias

This allows more accurate interpretation in highly myopic patients, where conventional normative databases may be less reliable.

Optional AngioScan OCT Angiography

The optional AngioScan OCT-A module provides detailed, dye-free visualisation of retinal and choroidal microvasculature.

Features include:

  • 6 × 6mm scans
  • 9 × 9mm scans
  • 12 × 12mm wide-field OCT-A
  • Vessel density maps
  • Perfusion density analysis
  • FAZ analysis

The wider OCT-A scan area improves assessment of retinal vascular disease whilst maintaining excellent image quality.

Intelligent Automation

The RS-1 Glauvas simplifies image acquisition through:

  • Auto Alignment
  • Auto Switch
  • Preset scan protocols
  • Customisable Combo Image Capture
  • Automated optimisation

Operators simply align the patient and initiate capture, making the system suitable for both experienced clinicians and trained technicians.

Enhanced SLO Imaging

Improved Scanning Laser Ophthalmoscopy (SLO) sensitivity enables reliable imaging, even in patients with:

  • Cataracts
  • Mild media opacities
  • Diabetic retinopathy
  • Reduced fixation

This enhances pre-operative assessment and improves image acquisition across a broader patient population.

OCT Viewer Software

The intuitive OCT Viewer provides:

  • Rapid image review
  • Side-by-side comparison
  • Summary analysis
  • Retina analysis
  • Glaucoma analysis
  • Macular analysis

Clinicians can quickly switch between imaging modes and review longitudinal patient data within a streamlined interface.

Clinical Applications

Glaucoma Diagnosis & Monitoring

Advanced RNFL, GCC and optic nerve analysis support early glaucoma detection and long-term disease monitoring, including patients with high myopia.

Medical Retina

High-resolution OCT imaging supports diagnosis and management of:

  • Age-related macular degeneration (AMD)
  • Diabetic macular oedema
  • Epiretinal membrane
  • Macular holes
  • Retinal vein occlusion

Wide-field imaging provides comprehensive assessment of retinal pathology.

Retinal Vascular Disease

Optional OCT Angiography allows non-invasive evaluation of retinal perfusion and microvascular abnormalities without intravenous dye injection.

High Myopia Assessment

Deep imaging and dedicated axial length compensation improve structural assessment in highly myopic eyes, supporting more accurate glaucoma evaluation.

Benefits for Your Practice

Improve Clinical Efficiency

Ultra-fast scanning and intelligent automation help reduce examination times while maintaining excellent image quality.

Increase Diagnostic Confidence

AI-powered segmentation and Structural Normality Mapping provide clearer, more reliable analysis of glaucoma and retinal disease.

Optimise High-Volume Clinics

Automated image capture, preset scan protocols and intuitive software improve workflow and reduce operator workload.

Enhance Patient Experience

Faster examinations and improved fixation compensation create a more comfortable experience, particularly for elderly and visually impaired patients.

Future-Proof Your Diagnostic Service

Expandable OCT Angiography, advanced analytics and ongoing software development ensure the RS-1 Glauvas continues to meet evolving clinical needs.

Ideal For

The NIDEK RS-1 Glauvas OCT is ideally suited to:

  • Hospital eye departments
  • Ophthalmology clinics
  • Glaucoma specialists
  • Medical retina clinics
  • High-volume diagnostic centres
  • Academic and research institutions

Its combination of ultra-fast imaging, AI-assisted analysis and comprehensive glaucoma and retinal assessment makes it one of NIDEK’s most advanced OCT platforms for modern ophthalmic practice.

Why Buy from Birmingham Optical?

Birmingham Optical provides:

  • Expert OCT consultation and workflow planning
  • Professional installation and clinical training
  • Dedicated application and technical support
  • Preventative servicing and maintenance
  • Access to the latest NIDEK ophthalmic technologies

As the exclusive distributor of NIDEK ophthalmic equipment across the UK and Ireland, Birmingham Optical provides comprehensive support to help practices maximise the value of their investment.

Find Out More

Discover how the NIDEK RS-1 Glauvas OCT can transform glaucoma and retinal diagnostics with ultra-fast 250kHz imaging, advanced deep learning analytics and intelligent workflow automation. Designed for today’s high-volume eye care environments, the RS-1 Glauvas delivers the speed, accuracy and clinical insight needed to support confident diagnosis and long-term patient management.

Contact Birmingham Optical today to speak with one of our ophthalmic equipment specialists on 0808 123 2020 or email [email protected] 

At Birmingham Optical we also supply a variety of smaller items, accessories and consumables, please visit our store here

  • NIDEK RS-1 Easy Start Up Guide Download